Construction Data FG7(O)R | ||||||||
Number of conductors | Rated cross-section | Diameter of the core | Average thickness of insulation | Cable diameter | Cable weight, approx. | El. resistance at 20°С | Current loading alowed (А) | |
mm2 | mm | mm | mm | kg/km | Ohm/km | 30°С in a tube or in the air | 20°С underground | |
1х | 1.5 | 1.6 | 0.7 | 6.05 | 51 | 13.3 | 20 | 21 |
2.5 | 2 | 0.7 | 6.5 | 63 | 7.98 | 28 | 27 | |
4 | 2.6 | 0.7 | 7.25 | 84 | 4.95 | 37 | 35 | |
6 | 3.4 | 0.7 | 7.7 | 104 | 3.3 | 48 | 44 | |
2x | 1.5 | 1.6 | 0.7 | 9.86 | 125 | 13.3 | 22 | 23 |
2.5 | 2 | 0.7 | 10.59 | 1.51 | 7.98 | 30 | 30 | |
|
|
| ||||||
Зх | 1.5 | 1.6 | 0.7 | 10.39 | 142 | 13.3 | 19.5 | 19 |
2.5 | 2 | 0.7 | 11.31 | 185 | 7.98 | 26 | 25 | |
4 | 2.6 | 0.7 | 12.71 | 246 | 4.95 | 35 | 32 | |
6 | 3.4 | 0.7 | 13.78 | 317 | 3.3 | 44 | 41 | |
4Х | 1.5 | 1.6 | 0.7 | 11.24 | 171 | 13.3 | 19.5 | 19 |
2.5 | 2 | 0.7 | 12.33 | 222 | 7.98 | 26 | 25 | |
4 | 2.6 | 0.7 | 13.9 | 294 | 4.95 | 35 | 32 | |
6 | 3.4 | 0.7 | 14.99 | 386 | 3.3 | 44 | 41 | |
10 | 4.4 | 0.7 | 18.27 | 611 | 1.91 | 60 | 55 | |
16 | 5.7 | 0.7 | 21.59 | 886 | 1.21 | 80 | 72 | |
25 | 6.9 | 0.9 | 24.26 | 1255 | 0.78 | 105 | 93 | |
5G | 1.5 | 1.6 | 0.7 | 11.97 | 197 | 13.3 | 19.5 | 19 |
2.5 | 2 | 0.7 | 13.38 | 266 | 7.98 | 26 | 25 | |
4 | 2.6 | 0.7 | 15.14 | 361 | 4.95 | 35 | 32 | |
6 | 3.4 | 0.7 | 16.45 | 471 | 3.3 | 44 | 41 | |
7х | 1.5 | 1.6 | 0.7 | 12.79 | 238 | 13.3 | 19.5 | 19 |
2.5 | 2 | 0.7 | 14.54 | 329 | 7.98 | 26 | 25 | |
|
|
|
|
|
|
|
|
|
10х | 1.5 | 1.6 | 0.7 | 15.24 | 334 | 13.3 | 35 | 19 |
2.5 | 2 | 0.7 | 17.2 | 466 | 7.98 | 26 | 25 | |
12х | 1.5 | 1.6 | 0.7 | 16.62 | 380 | 13.3 | 19.5 | 19 |
|
|
|
|
|
|
|
| |
| 2.5 | 2 | 0.7 | 18.53 | 754 | 7.98 | 26 | 25 |
16х | 1.5 | 1.6 | 0.7 | 19.67 | 549 | 13.3 | 19.5 | 19 |
2.5 | 2 | 0.7 | 22.06 | 848 | 7.98 | 26 | 25 | |
19х | 1.5 | 1.6 | 0.7 | 20.54 | 612 | 13.3 | 19.5 | 19 |
2 5 | 2 | 0 7 | 23.09 | 1049 | 7 98 | 26 | 25 | |
|
|
|
|
|
|
|
|
|
24х | 1.5 | 1.6 | 0.7 | 22.93 | 733 | 13.3 | 19.5 | 19 |
2.5 | 2 | 0.7 | 26.26 | 1140 | 7.98 | 26 | 25 | |
|
|
|
|
|
|
|
|
|
27х | 1.5* | 1.6 | 0.8 | 23.99 | 829 | 13.5 | 15 | 19 |
2.5* | 2 | 0.8 | 26.78 | 1234 | 8.1 | 20 | 25 | |
ЗОх | 1.5* | 1.6 | 0.8 | 24.77 | 894 | 13.5 | 15 | 19 |
2.5^ | 2 | 0.8 | 27.64 | 1331 | 8.1 | 20 | 25 |
Item No | Description | Producer |
FGOR_3_015 | Conductor FG7(O)R 3 x 1.5 mm² /non-flammable/ | |
FGOR_3_025 | Wire FG7(O)R 3 x 2,5 mm² /Flame retardant/ | |
FGOR_4_025 | Wire FG7(O)R 4 x 2,5 mm² /Flame retardant/ | |
FGOR_4_04 | Conductor FG7(O)R 4 x 4 mm² /non-flammable/ | |
FGOR_5_160 | Wire FG7(O)R 5 x 16 mm² /Flame retardant/ | |
PVA2_0950_FG7 | Wire FG7 450/700V 95 mm², PVC insulation, flexible copper cores |