The current clamp meters provide safe and non-contact measuring of currents up to 400A AC (СМ1-1, CM-1-2, CM-1-3, CM1), high currents up to 600/1000 A AC/DC. They are equipped with a voltage sensor, which signals for phase voltage with an acoustic signal and a red LED display. They localize cable breaks and defective lamps in exposed cables (cable reel, light chains) via the feeding side of the hase. Highest measuring category CAT IV 600 V allows measurements directly at the source of the low-voltage installation. Clamp meters are equipped with LC display and background illumination (for all types).
Digital Current Clamp Multimeter/Current Clamp Adapter | |||||||
| BENNING CC1 | BENNING CC2 | BENNING CM 1-1 | BENNING CM 1-2 | BENNING CM 1-3 | BENNING CM 2 | BENNING CM3 |
indicating range | - | - | 2000 | 2000 | 2000 | 4000 | 2000 |
basic accuracy | 1.9 % | 1 % - 3 % | 2% | 1 % | 1 % | 0.5 % | 1.9 % |
AC voltage | - | - | - | 0.1 V-600V | 0.1 V-750V | 0.1 mV-600V | - |
DC voltage | - | - | - | 0.1 V-600V | 0.1 V-1000 V | 0.1 mV-600V | - |
AC current | 1 A - 400 A | 0.5 A-200 A | 10 mA-400 A | 0.1 A-400 A | 0.1 A-200 A | 10 mA-300 A | 0.1 A-600 A |
DC current | - | - | - | - | - | 10 mA-300 A | 0.1 A-600 A |
resistance | - | - | - | 0.1 Q-20MQ | 0.1 Q-20MQ | 0.1 Q-40MQ | - |
continuity/diode | -/- | -/- | -/- | yes/- | yes/yes | yes/- | -/- |
frequency | - | - | - | - | - | - | - |
effective power | - | - | - | - | - | - | - |
power factor (cos φ | - | - | - | - | - | - | - |
temperature | - | - | - | - | - | - |
|
volt sensor | - | - | - | - | yes | - | - |
memory | - | - | HOLD, MAX | HOLD | HOLD | HOLD, MAX | HOLD |
measuring method | - | - | RMS | RMS | RMS | RMS | RMS |
max, damp opening | 30 mm | 21 mm | 30 mm | 30 mm | 16 mm | 25 mm | 38 mm |
measuiing category | CAT III 300 V | CAT III 600 V | CAT III 600 V | CAT III 600 V | CAT IV 600 V | CAT III 300 V | CAT III 300 V |
item no. | 44037 | 44110 | 44061 | 44062 | 44063 | 44035 | 44031 |
| BENNING CM 4 | BENNING CMS | BENNING CM 5-1 | BENNING CM 6 | BENNING CM 7 | BENNING CM 8 | BENNING CM 9 |
indicating range | 4000 | 4000 | 9999 | 4000 | 4000 | 6000 | 6000 |
basic accuracy | 0.7 % | 0.7 % | 0.9 % | 0.7 % | 0.7 % | 0.7 % | 1 % |
AC voltage | 0.1 V-600 V | 0.1 V-600 V | 1.3 V-750 V | 0.1 V-750 V | 0.1 V-750 V | 10 mV-1000 V | - |
DC voltage | 0.1 V-600 V | 0.1 V-600 V | 0.7 V-1000 V | 0.1 V-1000 V | 0.1 V-1000 V | 10 mV-1000 V | - |
AC current | 0.1 A-600 A | 0.1 A-600 A | 0.9 A-600 A | 0.1 A-1000 A | 0.1 A-1000 A | 0.1 A-600 A | 1 [JA-100A |
DC current | - | 0.1 A-600 A | 0.9 A-600 A | - | 0.1 A-1000 A | 0.1 A-600 A | - |
resistance | 0.1 Q - 400 Q | 0.1 Q - 400 Q | 0.1 Q-10kQ | 0.1 Q - 400 Q | 0.1 Q - 400 Q | 0.1 Q - 20 kQ | - |
continuity/diode | yes/- | yes/- | yes/yes | yes/- | yes/- | yes/yes | -/- |
frequency | 1 Hz - 400 Hz | 1 Hz - 400 Hz | - | 1 Hz - 400 Hz | 1 Hz - 400 Hz | 0.1 Hz-4 kHz | - |
effective power | - | - | - | - | - | 1 W - 600 kW | - |
power factor (cos φ | - | - | - | - | - | ±0.00-1.00 | - |
temperature | - | - | - | - | - | -50 "Cup to+1000 °C | - |
volt sensor | - | - | - | - | - | - | - |
memory | HOLD, MAX/MIN PEAK | HOLD, MAX/MIN PEAK, ZERO | HOLD | HOLD, MAX/MIN PEAK | HOLD, MAX/MIN PEAK, ZERO | HOLD, MAX/MIN PEAK, INRUSH | HOLD,PEAK |
measuring method | RMS | TRUE RMS | TRUE RMS | RMS | TRUE RMS | TRUE RMS | RMS |
max, damp opening | 37 mm | 45 mm | 35 mm | 53 mm | 53 mm | 40 mm | 40 mm |
measuiing category | CAT III 600 V | CAT III 600 V | CAT IV 600 V | CAT IV 600 V | CAT IV 600 V | CAT III 600 V | CAT III 300 V |
item no. | 44056 | 44057 | 44066 | 44058 | 44059 | 44064 | 44065 |
| Item No | Description | Producer |
| AK_Benning_CC1 | Digital Current Clamp Mutimeter Benning CC1 1-400Aac output 1mV/1A ф30mm, Benning 044037 | Benning GmbH |
| AK_Benning_CM_P2 | Clamp meter Benning CM P2 - 10mA-400A AC/DC, max. Ø23 mm, volt sensor, CAT III 600 V, 044679 | Benning GmbH |
| AK_Benning_CM1_1 | Digital Current Clamp Mutimeter Benning CM1-1 0.1-400Aac 30mm, Benning 044061 | Benning GmbH |
| AK_Benning_CM1_2 | Digital Current Clamp Mutimeter Benning CM1-2 0.1-400Aac 600Vac/dc 20MOhm 30mm, Benning 044062 | Benning GmbH |
| AK_Benning_CM1_3 | Digital Current Clamp Mutimeter Benning CM1-3 0.1-200Aac 750Vac/1000dc 20MOhm 16mm, Benning 044063 | Benning GmbH |
| AK_Benning_CM11 | Clamp meter Benning CM 11 - 0.01 V-600 V/AC, 0.1 mV -600 V/DC, 0.1 mA-20 A/AC, 0.1 mA -10 A /DC, 0.1 ohm-600 kΩ, continuity, max. Ø23 mm, CAT IV 300 V, 044067 | Benning GmbH |
| AK_Benning_CM12 | Clamp meter Benning CM 12 - 10 mV -1000 V AC/DC, 10 mA-600 A AC/DC, 0.1 ohm-100 kΩ, continuity, 0.01 Hz - 10 kHz, 1 nF - 4 mF, 1 W - 600 kW, power factor, max. Ø33 mm, CAT III 1000 V, CAT IV 600 V, 044680 | Benning GmbH |
| AK_Benning_CM1-4 | Digital Current Clamp Benning CM 1-4 - 10 mV -1000 V AC/DC, 10 mA-600 A AC/DC, 0.1 ohm-100 Kohm, continuity test, 0.01 Hz - 10 kHz, 1 nF - 4 mF, 1 W - 600 kW, power factor, макс. Ф19 mm, CAT III 1000 V, CAT IV 600 V, 044686 | Benning GmbH |
| AK_Benning_CM2 | Digital Current Clamp Mutimeter Benning CM2 0.1..300Aac/dc; 600Vac/d;c 40MhOm; ф25mm, Benning 044035 | Benning GmbH |
| AK_Benning_CM2-1 | Clamp meter Benning CM 2-1 - 10 mV -600 V AC/DC, 10 mA-400 A AC/DC, 0.1 ohm-100 kΩ, continuity, 0.01 Hz - 10 kHz, 1 nF - 4 mF, 1 W - 600 kW, power factor, max. Ø19 mm, CAT III 600 V, CAT IV 300 V, 044689 | Benning GmbH |
| AK_Benning_CM3 | Digital Current Clamp Mutimeter Benning CM3 0.1-600Aac/dc ф42mm, Benning 044031 | Benning GmbH |
| AK_Benning_CM4 | Digital Current Clamp Mutimeter Benning CM4 600Aac; 600Vac/dc; 400Ohm; 10kHz; continuity test; ф37mm; IEC61010, Benning 044056 | Benning GmbH |
| AK_Benning_CM5 | Digital Current Clamp Mutimeter Benning CM5 600Aac/dc; 600Vac/dc; 400Ohm; 4MHz; continuity test 30Ohm; ф45mm; IEC61010, Benning No.044057 | Benning GmbH |
| AK_Benning_CM5_1 | Digital Current Clamp Mutimeter Benning CM5-1 750/1000Aac/dc; 600Vac/dc; 1000Ohm; 4MHz; continuity test 30Ohm; ф35mm; IEC61010, Benning No.044066 | Benning GmbH |
| AK_Benning_CM6 | Digital Current Clamp Mutimeter Benning CM6 1000Aac; 750Vac/1000Vdc; 400Ohm; 10kHz; continuity test 30Ohm; ф53mm; IEC61010, Benning No.044058 | Benning GmbH |
| AK_Benning_CM7 | Digital Current Clamp Mutimeter Benning CM7 1000Aac; 750Vac/1000Vdc; 400Ohm; 4MHz; continuity test; ф53mm; IEC61010, Benning No.044059 | Benning GmbH |
| AK_Benning_CM8 | Digital Current Clamp Mutimeter Benning CM8 1000Aac; 1000Vac/1000Vdc; 600Ohm; 4MHz; continuity test; ф40mm; IEC61010, Benning No.044064 | Benning GmbH |
| AK_Benning_CM9 | Digital Current Clamp Mutimeter Benning CM9 1micr.А -100Aac, current leakage, ф40mm; IEC61010, Benning No.044065 | Benning GmbH |